• Electronic air displacement pipetting module in 3 configurations
  • Exceptional precision and accuracy
  • Configurable for mounting to a robotic arm
  • Interfaces with the M-Series motion controllers
  • Available in 200 μL, 1000 μL, 2000 μL and 5000 μL
  • Disposable Tip sizes 100 μL, 1000 μL, 2000 μL, 5000 μL
  • Tip Adapter option available

TriContinent Air-Z Legacy Series air displacement pumps are electronic air displacement pipette pumps designed to use liquid handling (XYZ) robotic systems. Thanks to TriContinent ADP pumps you can eliminate tubing and priming requirements usually associated with routine liquid handling tasks. At the same time, the precision and accuracy of the pump exceed that of any similarly sized handheld micropipette.

The compact and lightweight robotic pipette pump

The Air-Z Legacy’s simple mechanical interface makes it easy to integrate with liquid handling robotic systems. Developers can use their drivers for the Air-Z Legacy Series Pipette Pump or match the M-Series motion controller to provide a complete package.

Air-Z Legacy provides accuracy and precision for liquid handling applications

Syringe driven by the stepper motor will accurately and precisely handle fluid volumes from a few microliters to 5 milliliters. Using the TriContinent disposable tips, you can accurately and precisely perform sample transfers or reagent aliquoting without the risk of cross-contamination and carryover.

The flexibility of available configurations

TriContinent’s Air-Z Legacy Series air displacement pipette pumps are available version with or without the Proximity Sensor, as well as Instrument Ready configuration. Details can be found on the accessory tab on the liquid handling robot Page.

Air-Z Flex

Automated air displacement pipetting module available with or without control electronics and pressure sensor.

TriContinent Air-Z Flex ADP Pumps

Air-Z Legacy

TriContinent's first air displacement pipette with proven technology for use on liquid handling robotic systems.

Automated air displacement pipetting module air z legacy z pump 460

Air-Z Premier

Fully-featured, fully programmable air-displacement pipetting module with integrated tip ejection and automatic detection of liquid levels, tips, tip blockage, step loss and more.

Automated air displacement pipetting module air z premier air z premier 1

Air-Z FEATURES

Air-Z Premier

Air-Z Flex

Air-Z Legacy

High-resolution encoder (step loss detection)

Liquid level detection: pressure (pLLD)

Liquid level detection: capative & hybrid (cLLD & hLLD)

Real time streaming pressure data

Quiet at all speeds

Built-in tip ejector

Clogged tip detection

Option

Fully programmable (w/control electronics)

Option

Optional horizontal or vertical mounting orientation

Pump volume options

1000 μl

50 μl, 250 μl, 1000 μl

20 μl, 1000 μl, 2000 μl, 5000 μl

Tip volume availability

20 μl, 50 μl, 200 μl, 1000 μl

20 μl, 50 μl, 200 μl, 1000 μl

20 μl, 50 μl, 200 μl, 1000 μl

Overall dimensions without disposable tip (H x W x D)

168.7 mm x 60.5 mm x 30.5 mm

130.5 mm x 30.6 mm x 25.0 mm

131 mm x 47 mm

Driver Recommendations

  • Pump should typically be driven wtih a 24 VDC bipolar chopper drive, 1/2 step, at rated current. Bigher voltage may be require at higher step rates.

Fluid Contact Materials (in case of accidental fluid aspiration)

  • Acetal, PTFE, Silicone Lubricant, Buna N, Neoprene, Borosilicate Glass and Stainless Steel
 200ul_8_.png
 1000ul_1_.png
2000_ul_1_.png
 5000_ul.png

Note: Each tip is designed to seal within the reference gap dimensions shown. Customers should perform their own testing to determine optimum force/location for sealing and tip stripping.

 mkt90024_2_.gif

Dimensions/Features noted are typical for any size Z-Series pump (5000 µL shown)

Please contact your TriContinent Sales Representative for current pricing.

Pumps Without Tip Adapter

Catalog #

Description

948

Z-Pump, 200 μL

949

Z-Pump, 1000 μL

950

Z-Pump, 2000 μL

951

Z-Pump, 5000 μL

Racked Tips

Catalog #

Description

10000

200 μL Tips

10001

1000 μL Tips

10002

2000 μL Tips

10003

5000 μL Tips

Tip Adapters

Catalog #

Description

10005

200 μL

10006

1000 μL

10007

2000 μL

10008

5000 μL

M-Series Controller PCBA

Catalog #

Description

955

Controller/Driver for Z-pump (.5A Max)

959

RS232/485 Converter Kit

960

USB/485 Converter Kit

Z-Series Warranty Information

TriContinent operates an ISO 13485 registered manufacturing facility that delivers the highest quality products. Z-Series Pumps are general laboratory components not subject to FDA regulatory approval. TriContinent uses the highest quality components with applicable safety markings to meet the needs of system designers. Z-Series Pumps do not carry independent CE markings as they are components designed for use within larger systems which are subject to independent testing and certification.

We stand behind the Z-Series Pumps with a 1-year warranty. During the warranty period, should a Z-Series Pump fail, call us with an explanation of malfunction and TriContinent will issue a Return Material Authorization (RMA) number for repair or replacement at our discretion, at no charge.

It is the responsibility of the customer to determine the suitability of an application and the material compatibility of our product with your application.

When returning a product for repair or replacement, please contact TriContinent Customer Service to receive an RMA number. When calling please be sure to have the following information available:

  • Catalog Number
  • Serial Number
  • Explanation of Malfunction

TriContinent will not accept the return of any product with out prior approval. TriContinent reserves the right to refuse a return of product that has been used with infectious microbiological or radioactive substances or any other materials that may be deemed hazardous.

The RMA number should be referenced on the outside of the shipping container when returning to TriContinent.

Warranty Exlusions

The above warranty shally not apply for defective products resulting from:

  • Improper or Inadquate maintenance by the customer
  • Unauthorized maintenance or service
  • Customer misuse
  • Operation outside of environmental specifications for the product
  • Instruments returned without proper packagings

Note: For equipment damaged in shipping, please contact the shipper directly.