• Automated air displacement pipettor module with high resolution encoder for dependable step loss detection
  • Horizontal and vertical mounting configurations
  • Compact design
  • Available in 50 µL, 250 µL, and 1000 µL volumes
  • Optional pressure sensor and control electronics
  • Prevention of cross contamination and carryover during sample transfer and reagent aliquoting
  • No tubing and priming required
  • Custom tip adaptors, orientations and sizes to fit your instrument design
  • Optional tip adaptor and disposable tips

Air-Z Flex

Automated air displacement pipetting module available with or without control electronics and pressure sensor.

TriContinent Air-Z Flex ADP Pumps

Air-Z Legacy

TriContinent's first air displacement pipette with proven technology for use on liquid handling robotic systems.

Automated air displacement pipetting module air z legacy z pump 460

Air-Z Premier

Fully-featured, fully programmable air-displacement pipetting module with integrated tip ejection and automatic detection of liquid levels, tips, tip blockage, step loss and more.

Automated air displacement pipetting module air z premier air z premier 1

Air-Z FEATURES

Air-Z Premier

Air-Z Flex

Air-Z Legacy

High-resolution encoder (step loss detection)

Liquid level detection: pressure (pLLD)

Liquid level detection: capative & hybrid (cLLD & hLLD)

Real time streaming pressure data

Quiet at all speeds

Built-in tip ejector

Clogged tip detection

Option

Fully programmable (w/control electronics)

Option

Optional horizontal or vertical mounting orientation

Pump volume options

1000 μl

50 μl, 250 μl, 1000 μl

20 μl, 1000 μl, 2000 μl, 5000 μl

Tip volume availability

20 μl, 50 μl, 200 μl, 1000 μl

20 μl, 50 μl, 200 μl, 1000 μl

20 μl, 1000 μl, 2000 μl, 5000 μl

Overall dimensions without disposable tip (H x W x D)

168.7 mm x 60.5 mm x 30.5 mm

130.5 mm x 30.6 mm x 25.0 mm

131 mm x 47 mm

Drive Design

Stepper motor driven linear actuator with high resolution optical encoder for step loss detection

Dispense Speed

Pump volume 1000 μL: 1 μL/second up to 1800 ul/secondPump volume 250 μL: 1 μL/ second up to 450 μL/secondPump volume 50 μL: 1 μL/second up to 150 μL/second

Volume Resolution

Pump volume 1000 μL: 0.301 μL/half step increment with 3700 increments/full strokePump volume 250 μL: 0.075 μL/half step increment with 3500 increments/full strokePump volume 50 μL: 0.025 μL/half step increment with 2500 increments/full stroke

Communication Interfaces

RS232, RS485, or CAN

Addressing

Maximum of 15 pumps individually

Operating Noise

<60 dBA, Indoor use only

Operating Temperature Operating Humidity

15°C to 40°C (59°F to 104°F)20 to 95% RH at 40°C (104°F)

Non-Operating Temperature Non-Operating Humidity

-20°C to 65°C (-4°F to 149°F)30% to 85% RH non-condensing

Media Temperature

15°C to 40°C (59°F to 104°F)

Overall Dimensions (H x W x D)(with full electronics with tip adapter and without disposable tip)

Vertical orientation: 5.13 in [130.4 mm] x 1.20 in. [30.6 mm] x .83 in. [21.0 mm] Horizontal orientation: 2.11 in [53.6 mm] x 4.24 in. [107.7 mm] x .83 in. [21.0 mm]

Weight

125 gm

Fluid Contact Materials (in case of accidental fluid aspiration)

1000 μL & 250 μL—Acetal, PTFE, Silicone lubricant, Silicone, PPS, Neoprene, Borosilicate glass, Viton and Stainless steel 50 μL—Acetal, BunaN, Silicone lubricant, Silicone, PPS, Neoprene, Viton and Stainless steel

Functional Parameters with Full Electronics*

Imprecision (full volume) in 50 μL, 200 µL, 100 µL Tips

<0.75% CV

Inaccuracy (full volume)

<1% Tip volume

10% Tip volumes

 

Imprecision

<1% CV

Inaccuracy

<2%

Power Requirement

24VDC, 500 mA

Power Rating

<500 mA (peak)

*Specifications were determined gravimetrically using a precision balance, an automated robotic handling system withoptimized pump protocol, and tightly controlled environmental conditions; test temperature 23C ±2C, relative humidity35% ±5%, pump and test liquid (distilled water) temperature ≤ ±1 C of room temperature. Results may vary in otherenvironmental conditions, with other liquids, with disposable tips used, and depending on pump handling methods.

 

*Parameters without full electronics dependent on customer use

 air-z_flex_drawings_1.
 air-z_flex_drawings_2.p

Please contact your TriContinent Sales Representative for current pricing

Air-Z Flex, Vertical

Catalog #

Description

Contact us for details

Air-Z Flex, 1000 μL with no Electronics

Contact us for details

Air-Z Flex, 1000 μL with Pressure Sensor

10312

Air-Z Flex,1000 μL with Full Electronics

Contact us for details

Air-Z Flex, 250 μL with no Electronics

Contact us for details

Air-Z Flex, 250 μL with Pressure Sensor

10318

Air-Z Flex, 250 μL with Full Electronics

Contact us for details

Air-Z Flex, 50 μL with no Electronics

Contact us for details

Air-Z Flex, 50 μL with Pressure Sensor

10324

Air-Z Flex, 50 μL with Full Electronics

Air-Z Flex, Horizontal

Catalog #

Description

Contact us for details

Air-Z Flex, 1000 μL with no Electronics

Contact us for details

Air-Z Flex, 1000 μL with Pressure Sensor

10315

Air-Z Flex, 1000 μL with Full Electronics

Contact us for details

Air-Z Flex, 250 μL with no Electronics

Contact us for details

Air-Z Flex, 250 μL with Pressure Sensor

10321

Air-Z Flex, 250 μL with Full Electronics

Contact us for details

Air-Z Flex, 50 μL with no Electronics

Contact us for details

Air-Z Flex, 50 μL with Pressure Sensor

10327

Air-Z Flex, 50 μL with Full Electronics

Racked Tips

Catalog #

Description

10370

1000 μL Tips, Clear, Non-Sterile, Non-Filtered, 96/rack

10371

200 μL Tips, Clear, Non-Sterile, Non-Filtered, 96/rack

10372

50 μL Tips, Clear, Non-Sterile, Non-Filtered, 96/rack

10378

1000 μL Tips, LLD, Non-Sterile, Non-Filtered, 96/rack

10379

200 μL Tips, LLD, Non-Sterile, Non-Filtered, 96/rack

10380

50 μL Tips, LLD, Non-Sterile, Non-Filtered, 96/rack

Tip Adapters

Catalog #

Description

10009

Tip Adapter

Accessories

Catalog #

Description

Purpose

Product

10388

Cable Set (a 10-position flex cable interface PCBA and 10-position connector with 18” flying leads for the pump interface)

General-purpose evaluation cables

Air-Z Flex with full electronics, Air-Z Premier

10389

USB

and CAN bus/USB)

RS232 evaluation

Please contact customer service

TCS Air-Z Commander

RS232 evaluation

Air-Z Flex/Premier with full electronics

Please contact customer service

Terminal Emulator Program

RS232 evaluation

Air-Z Flex/Premier with full electronics

960

USB/RS485 Converter Kit

USB/RS485 evaluation

Air-Z Flex/Premier with full electronics

8698-03

USB A/B Cable

USB/RS485 evaluation

Air-Z Flex/Premier with full electronics

963

USB/CAN Bus Converter Kit

Adding CAN bus for data streaming hookup

Air-Z Flex/Premier with full electronics

959

RS232/485 Converter Kit

RS232 evaluation

Air-Z Flex/Premier with full electronics

Z-Series Warranty Information

TriContinent operates an ISO 13485 registered manufacturing facility that delivers the highest quality products. Z-Series Pumps are general laboratory components not subject to FDA regulatory approval. TriContinent uses the highest quality components with applicable safety markings to meet the needs of system designers. Z-Series Pumps do not carry independent CE markings as they are components designed for use within larger systems which are subject to independent testing and certification.

We stand behind the Z-Series Pumps with a 1-year warranty. During the warranty period, should a Z-Series Pump fail, call us with an explanation of malfunction and TriContinent will issue a Return Material Authorization (RMA) number for repair or replacement at our discretion, at no charge.

It is the responsibility of the customer to determine the suitability of an application and the material compatibility of our product with your application.

When returning a product for repair or replacement, please contact TriContinent Customer Service to receive an RMA number. When calling please be sure to have the following information available:

  • Catalog Number
  • Serial Number
  • Explanation of Malfunction

TriContinent will not accept the return of any product with out prior approval. TriContinent reserves the right to refuse a return of product that has been used with infectious microbiological or radioactive substances or any other materials that may be deemed hazardous.

The RMA number should be referenced on the outside of the shipping container when returning to TriContinent.

Warranty Exlusions

The above warranty shally not apply for defective products resulting from:

  • Improper or Inadquate maintenance by the customer
  • Unauthorized maintenance or service
  • Customer misuse
  • Operation outside of environmental specifications for the product
  • Instruments returned without proper packagings

Note: For equipment damaged in shipping, please contact the shipper directly.